SERVICES
Expert Medical Repair & Tech Support Services
Technology is constantly improving, enabling the end-user to work with more precision and efficiency. Oronix offers clients shorter turn around times without sacrificing superior repair service in the Canadian and US markets for a wide range of medical equipment. Clients are assured of unsurpassed service, quality components and reliable professional support. We can also supply the references of qualified physicians and engineers regarding our services.
Once a unit is received, it is analyzed, evaluated and a quote is prepared. After client approval, the unit is repaired and tested by an experienced professional. Repairs that are considered time sensitive (i.e., emergency) will be completed within the first 72-96 hours (subject to availability of parts). The unit is then returned with a warranty. Special instructions are included where necessary for your staff. No invoice will be issued until your satisfaction is confirmed.
Oronix’s staff works with its clients to jointly find long-range solutions. It is common to uncover weaknesses in design or workmanship that lead to repeated failures, excessive down time and replacement/repair cost. The experience that our technicians have acquired enables them to fully evaluate the devices, prepare accurate protocolsfor routine maintenance and provide technical training to a client’s technicians. This process helps clients to manage and positively affect biomedical/medical engineering operating costs.
Range of services include
Phaco Handpiece Repairs
REPAIRS
This service includes removal of stuck or broken tip, nose cone straightening, resurfacing and or straightening of damaged fitting, replacement of cable and connector. All repaired units are then tested for leaks and functioning to OEM specifications is ensured.
REBUILDS
Manufacturers Products That We Service:
- Optikon
- Bausch & Lomb®
- Nidek®
- STAAR
- Alcon
- Storz
- Mediphacos
- Geuder®
- Fritz Ruck
- AMO
- OMS
- Chiron
Repair and Rebuild of Finger Probe, Pulse Oximetry Sensor & Cable
Medical institutions today mostly use Nellcor, Ohmeda, CSI, BCI, Novametrix, In Vivo, Nonin and Space Labs Pulse Oximeter Sensors. Finger probes and pre-amp cables used to gather patient information develop defects during normal usage. The cost of new finger probes is very high, making repair and rebuild a cost effective alternative. Oronix provides you viable solutions for these units.
List of OEM (Original Equipment Manufacturer) Finger Probes we repair::
- BCI (Biochem Internatinal)
- CSI (Criticase Systems International )
- Datascope
- Datex- Ohmeda
- GE- Medical Systems
- HP (Hewlett Packard)
- Invivo Research
- Mallincrodt
- Nellcor
- Ninon
- Nova Metrix
- Pace Tech
- Philips Medical
- SensorMedics
- Siemens Medical
- Simed
- Spacelabs Medical
SPO2 Probes (Finger Sensor)
- Adult Clip SPO2 Sensor
- Ear Clip SPO2 Sensor
- SPO2 Adapter Cable
- SPO2 Extenstion Cable
- SPO2 Small Finger Clip Sensor (Child)
Fetal Ultrasound & Toco Transducers
Corometrics Fetal Ultrasound Transducer [Models 115, 116, 118, 120 Series]
Corometrics Fetal Toco Transducer [Models 115, 116, 118, 120 Series]
Hewlett Packard Fetal Ultrasound & Toco Transducer [Model 8040 and M1350A Series]
Spacelabs Fetal Ultrasound and Toco Transducers
Printed Circuit Boards & Repairs and Reworking
Cost-Saving PCB Repair & Evaluation
Service for X-Ray Tube Imaging Modalities
Additionally, we can provide many different types of diagnostic units such as:
- Machlett DX 62 series
- CGRStatorix
- Eimac B150 and B160 series
- Eureka Diamond and Sapphire
- General Electric HRT
- Maxiray 75 and 100
- Philips ROT 350
- Picker PX 1300 and 1400 series
- Siemens Bi 150 and Opti 150
- Many others
CT tube replacement line includes types for:
- Elscint
- General Electric
- Hitachi
- Philips
- Picker
- Shimadzu
- Siemens
- Toshiba
- Others
Suction Units
Most medical institutions use suction units made by Ohmeda, Chemetron/Vacutron and Ohio. The general tendency of hospitals is to discard these units when they fail. The primary reason is that spare part costs are very high. Oronix can provide a viable alternative to this situation.
Our approach for Repairs and Recovery
- Units are dismantled and thoroughly disinfected.
- Individual parts are cleaned with a chemical solution and put through an ultrasonic cleaning process.
- All cleaned parts are then tested with calibrated test jigs and only those working to OEM specifications are reused. Defective parts are replaced.
- The unit is then reassembled to OEM specifications.
- Our expertise and experience has shown that up to 60% of the scrapped units can be revived and guaranteed to function as specified by the OEM.
- The cost savings is significant, around 70% of replacement units.
Technical Training for BMETs
Each training module is based on the level and experience of BMETs. Classroom sessions extensively cover theory, applications, evolution of technology, electronic circuit analysis, usage of operating manuals, test equipment familiarization, statutory compliances, safety procedures, documentation and various other procedures. The equipment is dismantled completely during practical training and faults are simulated for troubleshooting practice. Stress is given on performing the appropriate tests at every stage of troubleshooting or preventive maintenance.
At Oronix, our philosophy is to help Biomeds do their job efficiently. In the process, we also take up work that is economically not viable at the actual work site.
Oronix offers technical training for the BMETs in following areas:
- Elscint
- General Electric
- Hitachi
- Philips
- Picker
- Shimadzu
- Siemens
- Toshiba
- Others
Our Commitment

Qualified, trained technicians provide reliable repairs for your products

6 month workmanship warranty on all repairs